COPPER PURITY TEST APPARATUS-BASIC

COPPER PURITY TEST APPARATUS

SCOPE
APPARATUS CONFINED TO OBTAIN PURITY OF COPPER UPTO 99.9 % BY ELECTROLYTIC METHOD. THIS METHOD REQUIRES A 0.001 MILI-GRAM WEIGHING SCALE (OPTIONAL), IN ORDER TO SEEK THE MOST PRECISE RESULTS, AS WELL AS NECESSARY TESTING PRECAUTIONS SHOULD BE TAKEN.

PRINCIPLE
THE SAMPLE COPPER IS DISSOLVE IN SULPHURIC- ACID NITRIC ACID MIXTURE AND COPPER DEPOSITED ELECTROLYTICALLY FROM THE SOLUTION. IN CASE OF COPPER, HAVING A PURITY OF LESS THAN 99.9 PERCENT, IMPURITIES ARE REMOVED BY FERRIC HYDROXIDE AND THEN COPPER DEPOSITED ELECTROLYTICALLY

APPARATUS COMPRISES OF:-
MAIN UNIT
COMPRISES OF DIGITAL INDICATOR OF AMPERE METER. ONE ON/OFF TOGGLE SWITCH MAINS INDICATOR LAMP, DIGITAL TEMP. CONTROLLER CUM INDICATOR, DIGITAL TIMER, EMERGENCY STOP AND MULTI TURN REGULATOR FOR THE AMPERE SETTING. OVERALL BODY IS POWDER COATED.
MAGNETIC STIRRER
CUBICAL BOX CONTAINS THE DC MOTOR AND HOT PLATE FOR THE BEAKER CONTAINING SOLUTION OF COPPER. SPEED OF DC MOTOR CONTROLLED BY REGULATOR. HEATING OF HOT PLATE CONTROLLED BY ENERGY REGULATOR. ONE MS ROD IS INSTALLED VERTICALLY AT THE REAR SIDE TO SUPPORT THE ACRYLIC BAR BEARING ELECTRODES. OVERALL BODY IS MADE OF MILD STEEL WITH HEAT RESISTANT PAINT.
LOAD CAPACITY 1 KW, 220 VOLTS AC.
ELECTRODES
CATHODE AND ANODE ARE MADE OF TITANIUM IRREDIUM ALLOY AND PLATED WITH PLATINUM COATING WITH SOME TREATMENT CONFIRMS THE GUIDELINES OF SAID SPECIFICATION.
CHEMICALS REQUIRED
SULPHURIC ACID. ONE BOTTLE 500ML.
NITRIC ACID ONE BOTTLE 500ML.

TECHNICAL SPECIFICATION
TEMP. RANGE 40 ° C ABOVE AMBIENT TO 150 °C
TEMP. CONTROL DIGITALLY CONTROLLED THROUGH DIGITAL TEMP. CONTROLLER CUM INDICATOR WITH SSR BASED CONTROL FOR BETTER ACCURACY
TEMP. SENSOR RTD TYPE PT 100 SENSOR
AMPERE METER 0~2.00 AMPERE DC. DIGITAL DISPLAY
ELECTRODES FABRICATED IN PLATINUM COATED ALLOY
POWER SUPPLY HIGH QUALITY COPPER WINDED TRANSFORMER DULY FIXED WITH PREMIUM HEAT SINK
DIMENSIONS 20” X 16” X 12” (L X B X H) APPROX
SUPPLY VOLTAGE REQUIRED 220-240 VAC 50 HZ
POWER CONSUMPTION LESS THEN 2 KW


SALIENT FEATURES
- THE TESTER MEETS WITH GOOD MARGIN, THE REQUIREMENTS IN IS: 191 & IS: 440-1984 OR ANY OTHER EQUIVALENT SPECIFICATION.
- THE CASING CONSISTS OF MILD STEEL DULY COATED WITH ATTRACTIVE POWDER PAINT.
- SEPARATE HEATING PLATE WITH STIRRER FOR CHEMICAL PREPERATION
- TEMPERATURE WOULD BE DIGITALLY CONTROLLED.
- SOLID STATE RELAY FOR SAFE CONTROL.
- RTD SENSOR WILL BE FITTED FOR THE PURPOSE.
- ELECTRODES ARE FABRICATED IN TITANIUM IRREDIUM ALLOY WITH PLATINUM COATING.
- AMPERE METER WITH 0.01 AMP RESOLUTION.
- PROVIDED WITH MULTI TURN PORT TO ADJUST THE AMPS, AS PER THE GUIDELINES MENTIONED IN ABOVE STANDARDS. - WE RESERVE THE RIGHT TO MODIFY THIS SPECIFICATION IN PART

PART LIST
PART NAME QUANTITY
MAIN CONTROL BOX ONE UNIT
HEATING CONTROL AND HEATING PLATE INBUILT IN MAIN CONTROL UNIT
GLASS BEAKER 250 ML ___ 01 UNIT
500 ML ___ 01 UNIT
ELECTRODES 01 SET. ONE SET CONTAINS CATHODE & ANODE
TEST LIDS ONE SET
ELECTRODE HOLDING ARRANGEMENT 01 UNIT. FABRICATED IN ACRYLIC AND STAINLESS STEEL
TEFLON MAGNET 02 UNITS
WORKING MANUAL SOFT COPY
CALIBRATION CERTIFICATES AT AN EXTRA COST